APPLY DICTIONARY
APPLY DICTIONARY FROM={'FILE_NAME',FILE_HANDLE}.
APPLY DICTIONARY
applies the variable labels, value labels, and
missing values taken from a file to corresponding variables in the
active dataset. In some cases it also updates the weighting variable.
The FROM
clause is mandatory. Use it to specify a system file or
portable file's name in single quotes, or a file handle
name. The dictionary in the
file is read, but it does not replace the active dataset's dictionary.
The file's data is not read.
Only variables with names that exist in both the active dataset and the system file are considered. Variables with the same name but different types (numeric, string) cause an error message. Otherwise, the system file variables' attributes replace those in their matching active dataset variables:
-
If a system file variable has a variable label, then it replaces the variable label of the active dataset variable. If the system file variable does not have a variable label, then the active dataset variable's variable label, if any, is retained.
-
If the system file variable has variable attributes, then those attributes replace the active dataset variable's variable attributes. If the system file variable does not have varaible attributes, then the active dataset variable's variable attributes, if any, is retained.
-
If the active dataset variable is numeric or short string, then value labels and missing values, if any, are copied to the active dataset variable. If the system file variable does not have value labels or missing values, then those in the active dataset variable, if any, are not disturbed.
In addition to properties of variables, some properties of the active file dictionary as a whole are updated:
-
If the system file has custom attributes (see DATAFILE ATTRIBUTE), then those attributes replace the active dataset variable's custom attributes.
-
If the active dataset has a weight variable, and the system file does not, or if the weighting variable in the system file does not exist in the active dataset, then the active dataset weighting variable, if any, is retained. Otherwise, the weighting variable in the system file becomes the active dataset weighting variable.
APPLY DICTIONARY
takes effect immediately. It does not read the
active dataset. The system file is not modified.